Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
15W883 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 3, CFM @ 0.100-In. SP 140, CFM @ 0.300-In. SP 116, CFM @ 0.400-In. SP 106, Voltage 120, 60 Hz, 1 Phase, 1.4 Max. Amps, Sensible Effectiveness (@ 32 F) 76, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140, Control Method Low Voltage, Defrost Type Recirculation, Height (In.) 17-29/32, Width (In.) 15, Length (In.) 22-13/32 |
FANTECH FLEX 100H |
15W884 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 3, CFM @ 0.100-In. SP 167, CFM @ 0.300-In. SP 150, CFM @ 0.400-In. SP 142, Voltage 120, 60 Hz, 1 Phase, 1.3 Max. Amps, Sensible Effectiveness (@ 32 F) 73, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140, Control Method Low Voltage, Defrost Type Recirculation |
FANTECH SHR 1505R |
15W885 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 3, CFM @ 0.100-In. SP 243, CFM @ 0.300-In. SP 218, CFM @ 0.400-In. SP 201, 182 CFM @ 0.500-In. SP, 166 CFM @ 0.600-In. SP, 151 CFM @ 0.700-In. SP, Voltage 120, 60 Hz, 1 Phase, 2.1 Max. Amps, Sensible Effectiveness (@ 32 F) 74, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140, Control Method Low Voltage, Defrost Type Recirculation |
FANTECH SHR 2005R |
15W886 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 3, CFM @ 0.100-In. SP 268, CFM @ 0.300-In. SP 246, CFM @ 0.400-In. SP 231, Voltage 120, 60 Hz, 1 Phase, 2.7 Max. Amps, Sensible Effectiveness (@ 32 F) 91, Total Recovery Efficiency (@ 95 F) 18, Latent Effectiveness (@ 95 F) 18, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140 |
FANTECH SHR 3005R |
15W887 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 3, CFM @ 0.300-In. SP 300, CFM @ 0.400-In. SP 261, Voltage 120, 60 Hz, 1 Phase, 2.5 Max. Amps, Sensible Effectiveness (@ 32 F) 77, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140, Control Method Low Voltage, Defrost Type Recirculation, Height (In.) 20-1/2 |
FANTECH SHR 3205RD |
15W888 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 3, CFM @ 0.100-In. SP 782, CFM @ 0.300-In. SP 711, CFM @ 0.400-In. SP 685, Voltage 120, 60 Hz, 1 Phase, 5.5 Max. Amps, Sensible Effectiveness (@ 32 F) 78, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140, Control Method Low Voltage, Defrost Type Recirculation |
FANTECH SHR 6905R |
15W889 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 3, CFM @ 0.400-In. SP 1064, 927 CFM @ 0.600-In. SP, Voltage 120, 60 Hz, 1 Phase, 11.0 Max. Amps, Sensible Effectiveness (@ 32 F) 77, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140, Control Method Low Voltage, Defrost Type Recirculation, Height (In.) 24, Width (In.) 51-3/8, Length (In.) 46-1/2, Vertical Mounting Location |
FANTECH SHR 11005R |
15W890 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 1, CFM @ 0.100-In. SP 96, CFM @ 0.300-In. SP 67, CFM @ 0.400-In. SP 56, Voltage 120, 60 Hz, 1 Phase, .36 Max. Amps, Sensible Effectiveness (@ 32 F) 57, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140, Control Method Low Voltage, Defrost Type Recirculation, Height (In.) 17-1/4, Width (In.) 10-1/4, Length (In.) 22-1/2, Vertical Mounting Location |
FANTECH VH 704 |
15W891 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 3, CFM @ 0.100-In. SP 96, CFM @ 0.300-In. SP 67, CFM @ 0.400-In. SP 56, 42 CFM @ 0.500-In. SP, 67 Efficiency, Voltage 120, 60 Hz, 1 Phase, .36 Max. Amps, Sensible Effectiveness (@ 32 F) 69, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140, Control Method Low Voltage, Defrost Type Recirculation, Height (In.) 17-5/8, Width (In.) 10-1/4, Length (In.) 22-1/2, Vertical Mounting Location |
FANTECH VHR 704 |
15W892 Grainger |
|
Heat Recovery Ventilator, Number of Speeds 3, CFM @ 0.100-In. SP 84, CFM @ 0.300-In. SP 64, CFM @ 0.400-In. SP 55, Voltage 120, 60 Hz, 1 Phase, .40 Max. Amps, Sensible Effectiveness (@ 32 F) 69, Wiring Method Plug, Motor Type External Rotor, Max. Inlet Temp. (Deg. F) 140, Control Method Low Voltage, Defrost Type Recirculation, Height (In.) 17-5/8, Width (In.) 10-1/4, Length (In.) 22-1/2, Vertical Mounting Location |
FANTECH VHR 704R |