13X132
Grainger
Подробнее... Earth Ground Tester, Earth Ground Resistance Range 0.002/0.02/0.2/2k Ohms, Resolution 0.001 to 1k Ohms, Operating Frequency 820 Hz, Accuracy +/-2 Percent of Reading +/-3 Digits, Measuring Current 2mAEarth Volts 0 to 300VACDisplay Dual Line LCD, Counts 20, 000, Power Source (8) 1.5V AA Batteries, Standards EN 61010-1, EN 61326-1, EN 61557-1, EN 61557-5, Pollution Degree 2, Safety Rating CAT IV 300VEarth Measurement Poles (4) Auxillary Earth Bars EXTECH
GRT300
1FBK4
Grainger
Подробнее... Earth Ground Tester, Earth Ground Resistance Range 0.001 to 19.99k Ohms, Resolution 0.001 to 10 Ohms, Operating Frequency 128 Hz, Accuracy +/-2 Percent of Reading +/-3 Digits or +/-7 Percent of Reading +/-3 Digits, Measuring Current Greater Than 50mA, Measuring Voltage Less Than =48V, Earth Volts 250VAC, Soil Resistivity Yes, Display LCD, Counts 1999, Power Source (6) AA Batteries, Standards CE, CSAEarth Measurement Clamps (1) Selective, (2) Stakeless, Earth Measurement Poles 34 FLUKE
FLUKE-1623
1FBK5
Grainger
Подробнее... Earth Ground Tester Kit, Earth Ground Resistance Range 0.001 to 19.99k Ohms, Resolution 0.001 to 10 Ohms, Operating Frequency 128 Hz, Accuracy +/-2 Percent of Reading +/-3 Digits or +/-7 Percent of Reading +/-3 Digits, Measuring Current Greater Than 50mA, Measuring Voltage Less Than =48V, Earth Volts 48VAC, Soil Resistivity Yes, Display LCD, Counts 1999, Power Source (6) AA Batteries, Standards CE, CSAEarth Measurement Clamps (1) Selective, (2) Stakeless, Earth Measurement Poles 34 FLUKE
FLUKE-1623 KIT
1FBK6
Grainger
Подробнее... Earth Ground Tester, Earth Ground Resistance Range 0.001 to 299.9k Ohms, Resolution 0.001 to 100 Ohms, Operating Frequency 94/105/111/128 Hz, Accuracy +/-2 Percent of Reading +/-2 Digits or +/-7 Percent of Reading +/-2 Digits, Measuring Current 250mA, Measuring Voltage 20/48V, Earth Volts 250VAC, Soil Resistivity Yes, Display LCD, Counts 2999, Power Source (6) AA Batteries, Standards CE, CSAEarth Measurement Clamps (1) Selective, (2) Stakeless, Earth Measurement Poles 2, 3, 4 (AC), 2 and 4 (DC) FLUKE
FLUKE-1625
1FBK7
Grainger
Подробнее... Earth Ground Tester Kit, Earth Ground Resistance Range 0.001 to 299.9k Ohms, Resolution 0.001 to 100 Ohms, Operating Frequency 94/105/111/128 Hz, Accuracy +/-2 Percent of Reading +/-2 Digits or +/-7 Percent of Reading +/-2 Digits, Measuring Current 250mA, Measuring Voltage 20/48V, Earth Volts 48VAC, Soil Resistivity Yes, Display LCD, Counts 2999, Power Source (6) AA Batteries, Standards CE, CSAEarth Measurement Clamps (1) Selective, (2) Stakeless, Earth Measurement Poles 2, 3, 4 (AC), 2 and 4 (D FLUKE
FLUKE-1625 KIT
24K395
Grainger
Подробнее... Earth Ground Tester, Earth Ground Resistance Range 0.00001 to 0.019/0.1999/1.999/19.99/49.9k Ohms, Resolution 0.01 to 1 Ohms, Operating Frequency 77.5 Hz, Accuracy +/-2 Percent of Reading +/-2 LSD, Measuring Current 12mA, Measuring Voltage Less Than =25V, Earth Volts 460VAC, Soil Resistivity Yes, Display LCD, Counts 2000Standards IEC, EN 61010-1, EN 1557-1, EN 1557-5, EN 61557-1/-5, EN 61326, Safety Rating CAT III 240V, Interface PC, Earth Measurement Clamps No, Earth Measurement Poles 4 AMPROBE
GP-2A
2FTY7
Grainger
Подробнее... Earth Ground Tester, Earth Ground Resistance Range 0.15 to 2k Ohms, Resolution 0.01 to 1 Ohms, Operating Frequency 128 Hz, Accuracy +/-6 Percent of Reading +/-5 Digits or +/-18 Percent of Reading +/-5 Digits, Measuring Current Greater Than 50mA, Measuring Voltage Less Than =48V, Earth Volts 250VAC, Soil Resistivity No, Display LCD, Counts 1999, Power Source (1) 9V Battery, Standards IEC, EN 61010-1, Pollution Degree 2, Safety Rating CAT II 600VEarth Measurement Poles 23 FLUKE
FLUKE-1621
2MY25
Grainger
Подробнее... Earth Ground Tester, Earth Ground Resistance Range 0.00001 to 2k OhmsOperating Frequency 128 Hz, Accuracy +/-2 Percent of Reading +/-3 Digits, Measuring Current 4.5mAEarth Volts 100VAC, Soil Resistivity Yes, Display Digital LCD, Counts 1999, Power Source (8) AA Batteries, Standards EN 61010-1, EN 61326-1, EN 61557-1, EN 61557-5, Safety Rating CAT IV 100VIncludes Carrying Case, Full Stake and Wire Test Kit, Batteries and Instructions, Manufacturers Warranty Length 3 yr. MEGGER
DET3TC
2MY35
Grainger
Подробнее... Earth Ground Tester, Earth Ground Resistance Range 0.01 to 99k OhmsOperating Frequency 40 to 513 Hz, Accuracy +/-2 Percent of Reading +/-1 Count, Measuring Current 250mAEarth Volts 16 to 32VAC, Soil Resistivity Yes, Display Digital LCD, Counts 1000, Power Source 9.6V Recharable Battery Pack, Standards EN 61010-1, Pollution Degree 2, Safety Rating CAT IV 50V, Interface USBIncludes Software, Battery Charger, AC Power Cord, NiMH Batteries, Interface Cable and Instructions AEMC
6470B
2T597
Grainger
Подробнее... Earth Ground Tester, Earth Ground Resistance Range 0.0005 to 1k Ohms, Resolution 0.01 to 1 Ohms, Operating Frequency 128 Hz, Accuracy +/-5 Percent of Reading, Measuring Current 10mADisplay AnalogPower Source (8) AA Batteries, Standards CE, EN 61010-1, EN 50081-1, EN 50082-1, Pollution Degree 2, Safety Rating CAT III 24VIncludes (8) 1.5V AA Batteries AEMC