ТЕЛ:+7 (985) 487-07-35
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Артикул
Каталог
Наименование
Описание Производитель
№ модели
13A868
Grainger
Подробнее... SoftwareHeight 1 In., Width 7-1/2 In., Depth 1 In. COOPER ATKINS
10400
13A869
Grainger
Подробнее... Base Station Buffer, 900 MHz RF Communication Method, Temp. Range (F) 32 Degrees to 140 Degrees , Temp. Range (C) 0 Degrees to 60 Degrees , Power Source 11-14VDC, 60 Hz, 80mA, External Transformer, Battery Life 2-5 yr., Height 9 In., Width 4 In., Depth 6 In., Wireless Range 2500 ft. (762m), Manufacturers Warranty Length 1 yr. COOPER ATKINS
10000-5-P-US
13A870
Grainger
Подробнее... Repeater, 900 MHz RF Communication Method, Temp. Range (F) 32 Degrees to 140 Degrees , Temp. Range (C) 0 Degrees to 60 Degrees Power Source 120VAC, Battery Life 2-5 yr.Height 4 In., Width 7 In., Depth 4 In., Wireless Range 2500 ft. (762m)Manufacturers Warranty Length 1 yr. COOPER ATKINS
10050-US
13A871
Grainger
Подробнее... Steam Trap Transmitter, 900 MHz RF Communication Method, Temp. Range (F) -40 Degrees to 392 Degrees , Temp. Range (C) -40 Degrees to 200 Degrees , Accuracy +/-5 Degrees F / +/-2.8 Degrees C, Power Source Battery, (2) 2/3A 3V Lithium, Battery Life 2-5 yr., Features Dual Probe, Height 4 In., Width 10 In., Depth 4 In., Wireless Range 2500 ft. (762m), Calibration Certificate NIST, Manufacturers Warranty Length 1 yr. COOPER ATKINS
10098
13A872
Grainger
Подробнее... Temperature/Humidity Transmitter, 900 MHz RF Communication Method, Temp. Range (F) -40 Degrees to 140 Degrees , Temp. Range (C) -40 Degrees to 60 Degrees , Relative Humidity Range 0 to 95 Percent, Accuracy +/-0.5 Degrees F (+/-0.3 Degrees C) at 77 Degrees F (25 Degrees C), Power Source 2/3 A Size LiMn02, Battery Life 2-5 yr., Features Internal Sensor, Height 3.5 In., Width 1.5 In., Depth 1 In., Wireless Range 2500 ft. (762m), Manufacturers Warranty Length 1 yr. COOPER ATKINS
10071
13A873
Grainger
Подробнее... Contact Transmitter, 900 MHz RF Communication Method, Temp. Range (F) -4 Degrees to 140 Degrees , Temp. Range (C) -20 Degrees to 60 Degrees , Power Source 2/3 A Size LiMn02, Battery Life 2-5 yr., Features Door Open/Close, Height 3.5 In., Width 1.5 In., Depth 1 In., Wireless Range 2500 ft. (762m), Manufacturers Warranty Length 1 yr. COOPER ATKINS
10100-DT
13A874
Grainger
Подробнее... Air Probe, -25 to 180 Degrees Temp. Range (F), -32 to 82 Degrees Temp. Range (C), Features .5 In. Probe, Height 1 In., Width 3 In., Depth 1 In. COOPER ATKINS
2033
13A875
Grainger
Подробнее... Glycol Probe, -25 to 180 Degrees Temp. Range (F), -32 to 82 Degrees Temp. Range (C), Features 6 In. Probe, Height 1 In., Width 6 In., Depth 1 In. COOPER ATKINS
10112
13A876
Grainger
Подробнее... Solid Probe, -25 to 180 Degrees Temp. Range (F), -32 to 82 Degrees Temp. Range (C), Features 1.5 In. Probe Dia., Height 4 In., Width 5 In., Depth 1 In. COOPER ATKINS
10113
13A877
Grainger
Подробнее... Temperature Transmitter, 900 MHz RF Communication Method, Temp. Range (F) -22 Degrees to 212 Degrees , Temp. Range (C) -30 Degrees to 100 Degrees , Accuracy 0.8F (0.5C) Internal, +/-1F external, Power Source 2/3 A Size LiMn02, Battery Life 2-5 yr., Features Internal/External Sensor, Height 1 In., Width 4 In., Depth 2.5 In., Wireless Range 2500 ft. (762m), Calibration Certificate NIST, Includes (1) 6 foot air probe, Manufacturers Warranty Length 1 yr. COOPER ATKINS
10080-DTG