Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
12U454 Grainger |
|
Pressure Level Transmitter, Submersible Wastewater Level Measurement, Range 5psi (11.55' WC), Accuracy +/- 0.25 Percent of Range, Configuration Factory Set, Voltage 10 to 28 VDC, Output 4-20 mA, 2-wire, Temp. Range 0 to 176 Degrees F, Proof Pressure 2 x full scale, Enclosure Material 316 SS, 316L SS, Buna-N, Mounting In-Tank, Lowest Level, Loop Resistance 900 Ohms, Cable Material Polyurethane, Cable Length 40', Cable Type Vented, Application Industrial Lift Stations, Waste Water, Length 7.98 In. |
FLOWLINE LD32-S301 |
12U455 Grainger |
|
Pressure Level Transmitter, Submersible Wastewater Level Measurement, Range 10psi (23.1' WC), Accuracy +/- 0.25 Percent of Range, Configuration Factory Set, Voltage 10 to 28 VDC, Output 4-20 mA, 2-wire, Temp. Range 0 to 176 Degrees F, Proof Pressure 2 x full scale, Enclosure Material 316 SS, 316L SS, Buna-N, Mounting In-Tank, Lowest Level, Loop Resistance 900 Ohms, Cable Material Polyurethane, Cable Length 40', Cable Type Vented, Application Industrial Lift Stations, Waste Water, Length 7.98 In. |
FLOWLINE LD32-S311 |
12U456 Grainger |
|
Pressure Level Transmitter, Submersible Wastewater Level Measurement, Range 15psi (34.65' WC), Accuracy +/- 0.25 Percent of Range, Configuration Factory Set, Voltage 10 to 28 VDC, Output 4-20 mA, 2-wire, Temp. Range 0 to 176 Degrees F, Proof Pressure 2 x full scale, Enclosure Material 316 SS, 316L SS, Buna-N, Mounting In-Tank, Lowest Level, Loop Resistance 900 Ohms, Cable Material Polyurethane, Cable Length 60', Cable Type Vented, Application Industrial Lift Stations, Waste Water |
FLOWLINE LD32-S321 |
12U457 Grainger |
|
Pressure Level Transmitter, Submersible Wastewater Level Measurement, Range 20psi (46.2' WC), Accuracy +/- 0.25 Percent of Range, Configuration Factory Set, Voltage 10 to 28 VDC, Output 4-20 mA, 2-wire, Temp. Range 0 to 176 Degrees F, Proof Pressure 2 x full scale, Enclosure Material 316 SS, 316L SS, Buna-N, Mounting In-Tank, Lowest Level, Loop Resistance 900 Ohms, Cable Material Polyurethane, Cable Length 60', Cable Type Vented, Application Industrial Lift Stations, Waste Water, Length 7.98 In. |
FLOWLINE LD32-S331 |
12U458 Grainger |
|
Ultrasonic Level Transmitter, Level Measurement, Classification Explosion Proof, Range 26.2', Accuracy +/- 0.2 Percent of Range, Resolution 0.079 In., Dead Band 8 In., Beam Width 3 In., Configuration Push Button, Input Voltage 18-28 VDC (loop), Output 4-20 mA, 2-wire, Temp. Range -4 to 140 Degrees F, Max. Pressure 30 psi, Enclosure Rating Type 4, Enclosure Material Aluminum, PVDF, Gasket Material Viton, Mounting 2 In. NPT, Display LCD, 6-digit, Standards FM, CE, RoHS, Length 4.44 In. |
FLOWLINE XP88-00 |
12U459 Grainger |
|
Ultrasonic Level Transmitter, Level Measurement, Classification Explosion Proof, Range 32.8', Accuracy +/- 0.2 Percent of Range, Resolution 0.079 In., Dead Band 8 In., Beam Width 3 In., Configuration Push Button, Input Voltage 18-28 VDC (loop), Output 4-20 mA, 2-wire, Temp. Range -4 to 140 Degrees F, Max. Pressure 30 psi, Enclosure Rating Type 4, Enclosure Material Aluminum, PVDF, Gasket Material Viton, Mounting 2 In. NPT, Display LCD, 6-digit, Standards FM, CE, RoHS, Length 4.44 In. |
FLOWLINE XP89-00 |
12U460 Grainger |
|
Ultrasonic Level Transmitter, Level Measurement, Classification Intrinsically Safe, Range 18.0', Accuracy +/- 0.25 Percent of Range, Resolution 0.125 In., Dead Band 6 In., Beam Width 8 Degrees Conical, Configuration Push Button, Input Voltage 12-32 VDC, Output 4-20 mA, 2-wire, Temp. Range -4 to 140 Degrees F, Max. Pressure 30 psi, Enclosure Rating NEMA 4X (IP65), Enclosure Material Polypropylene, PVDF, Gasket Material Viton, Mounting 2 In. NPT, Display LCD, 4-digit, Standards CSA, CE |
FLOWLINE LU20-5001 IS |
12U461 Grainger |
|
Leak Detection Switch, Interstitial, Horizontal Orientation, Contact Type 30 Watts, 240 VAC (0.14A resistive), 120 VAC (0.28A resistive), 120 VDC (0.07A resistive), 24 VDC (0.28A resistive), , Input Voltage 240 VAC/120 VDC max., Output SPST Reed, Temp. Range -40 to 221 Degrees F, Max. Pressure 50 psi, Foamed Polypropylene, Valox 420, Stainless Steel, Wire Type 2 conductor, #22 AWG, Jacket Material Halar Jacket, Standards CE, UL, Length 3.00 In., Width 1.50 In., Height 0.75 In. |
FLOWLINE LH29-1001 |
12U462 Grainger |
|
Drum Float Alarm, 55 Gallon Drum High, Vertical Orientation, LED Alarm Type, Input Voltage 9-Volt Battery, Temp. Range -40 to 302 Degrees F, Max. Pressure 250 psi, Enclosure Rating NEMA 4, Enclosure Material Polycarbonate, 316 Stainless Steel, Standards RoHS, CE, UL, Mounting 3/4 In. NPT, Specific Gravity 0.73 (+/- 0.02), Length 8 In., Width 2.5 In., Height 2.125 In. |
FLOWLINE AV17-S101 |
12U463 Grainger |
|
Drum Float Alarm, 55 Gallon Drum Low, Vertical Orientation, LED Alarm Type, Input Voltage 9-Volt Battery, Temp. Range -40 to 302 Degrees F, Max. Pressure 250 psi, Enclosure Rating NEMA 4, Enclosure Material Polycarbonate, 316 Stainless Steel, Standards RoHS, CE, UL, Mounting 3/4 In. NPT, Specific Gravity 0.73 (+/- 0.02), Length 37 In., Width 2.5 In., Height 2.125 In. |
FLOWLINE AV17-S201 |