Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
4XJZ5 Grainger |
|
Input Line Reactor, High Z, Voltage 480, Amps 77, 60 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 226, Impedance 5%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 19.13 In., Width 15.43 In., Depth 15.43 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULF2HE01 |
4XJZ6 Grainger |
|
Input Line Reactor, High Z, Voltage 480, Amps 96, 75 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 212, Impedance 5%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 19.13 In., Width 15.43 In., Depth 15.43 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULH2HE01 |
4XJZ7 Grainger |
|
Input Line Reactor, High Z, Voltage 480, Amps 124, 100 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 362, Impedance 5%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 19.13 In., Width 15.43 In., Depth 15.43 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULI2HE01 |
4XJZ8 Grainger |
|
Input Line Reactor, Low Z, Voltage 575/600, Amps 0.9, 0.5 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 6, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULA55LE01 |
4XJZ9 Grainger |
|
Input Line Reactor, Low Z, Voltage 575/600, Amps 1.3, 0.75 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 9.3, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULA56LE01 |
4XKA1 Grainger |
|
Input Line Reactor, Low Z, Voltage 575/600, Amps 1.7, 1 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 12, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULA50LE01 |
4XKA3 Grainger |
|
Input Line Reactor, Low Z, Voltage 575/600, Amps 2.7, 2 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 22, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULA46LE01 |
4XKA6 Grainger |
|
Input Line Reactor, Low Z, Voltage 575/600, Amps 9, 7.5 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 42.9, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULA48LE01 |
4XKA7 Grainger |
|
Input Line Reactor, Low Z, Voltage 575/600, Amps 11, 10 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 43.8, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULA49LE01 |
4XKA8 Grainger |
|
Input Line Reactor, Low Z, Voltage 575/600, Amps 17, 15 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 66.2, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified |
KDR-LINE REACTORS KDRULB45LE01 |