4FFJ6
Grainger
Подробнее... Immersion Temperature Probe, Air or Liquids, 100 Ohms Industrial PRT, -328 Degrees to 788 Degrees Temp. Range (F), Probe Connector Info-Con Smart Connector, Probe Material Stainless Steel, Wire Length 72 In., Probe Length 12 In., Probe Dia. 1/4 In., -200 Degrees to 420 Degrees Temp. Range (C), Accuracy +/-0.05 Degrees CFor Use With Mfr. No. 1523 to 156 and 1524 to 156, Calibration Certificate NISTManufacturers Warranty Length 1 yr. HART
5627A-12-P
4LGZ9
Grainger
Подробнее... Dry Well Calibrator, Temp. Range 95 Degrees to 707 Degrees F, 35 Degrees to 375 Degrees C, Temp. Accuracy +/-0.45 Degrees F at 122 Degrees F, +/-0.9 Degrees F at 707 Degrees F, +/- 0.25 Degrees C at 50 Degrees C; +/- 0.25 Degrees C at 100 Degrees C; +/- 0.5 Degrees C at 375 Degrees C, Temp. Stability +/- 0.07 Degrees C at 50 Degrees C; +/- 0.1 Degrees C at 100 Degrees C; +/- 0.3 Degrees C at 375 Degrees C, Stem Hole Dia. 0.0625 In., 0.125 In., 0.15625 In., 0.1875 In. and 0.25 In. Probes HART
9100S-A-156
4LHA1
Grainger
Подробнее... Dry Well Calibrator, Temp. Range 95 Degrees to 707 Degrees F, 36 Degrees to 375 Degrees C, Temp. Accuracy +/-0.45 Degrees F at 122 Degrees F, +/-0.9 Degrees F at 707 Degrees F, +/- 0.25 Degrees C at 50 Degrees C; +/- 0.25 Degrees C at 100 Degrees C; +/- 0.5 Degrees C at 375 Degrees C, Temp. Stability +/- 0.07 Degrees C at 50 Degrees C; +/- 0.1 Degrees C at 100 Degrees C; +/- 0.3 Degrees C at 375 Degrees C, Stem Hole Dia. 0.125 In., 0.1875 In., 0.25 In. and 0.375 In. Probes HART
9100S-B-156
4LHA2
Grainger
Подробнее... Dry Well Calibrator, Temp. Range 14 Degrees to 252 Degrees F, -10 Degrees to 122 Degrees C, Temp. Accuracy +/-0.45 Degrees F, +/-0.25 Degrees C, Temp. Stability +/- 0.05 Degrees C, Stem Hole Dia. 0.0625 In., 0.125 In., 0.1875 In., 0.25 In., 0.3125 In., 0.375 In., 0.4375 In. or 0.15625 In. Probes (Dependent on Inserts Used), Well Depth 4 In. (102mm), Removable Inserts Yes, Power Required 94 to 234VAC (+/-10 Percent), 50/60 Hz, Height 3.9 In., Width 5.5 In., Depth 6.9 In., Interface RS-232 HART
9102S-156
4LHA3
Grainger
Подробнее... Carrying Case, Material Plastic, Overall Height 4 In., Overall Width 9 In., Overall Depth 7 In., Color Black, For Use With Mfr. No. 9100, 9100S-A-156, 9100S-B-156, Manufacturers Warranty Length 1 yr. HART
9300
4LHA4
Grainger
Подробнее... Carrying Case, Material Plastic, Overall Height 5-1/2 In., Overall Width 11-1/2 In., Overall Depth 11-1/2 In., Color Black, For Use With Mfr. No. 9102S, 9102S-156Manufacturers Warranty Length 1 yr. HART
9308
4LHA6
Grainger
Подробнее... Dry Well Calibrator, Temp. Range Cold Block: 5 Degrees to 230 Degrees F, -15 Degrees to 110 Degrees C, Hot Block: 122 Degrees to 662 Degrees F, 50 Degrees to 350 Degrees C, Temp. Accuracy Cold Block: +/-0.36 Degrees F, +/-0.2 Degrees C, Hot Block: +/-1.08 Degrees F, +/-0.6 Degrees C, Temp. Stability +/- 0.05 Degrees C, Stem Hole Dia. 0.0625 In., 0.125 In., 0.1875 In., 0.25 In., 0.3125 In., 0.375 In., 0.4375 In. or 0.15625 In. Probes (Dependent on Inserts Used), Well Depth 4 In. (102mm) HART
9009-B-156
4LHA7
Grainger
Подробнее... Blank Stem Insert, For Use With Hart 9102S-156, 9009-Y-156 and 9009-B-156 HART
3102-0
4LHA8
Grainger
Подробнее... Stem Insert, Stem Size 1/16 In., For Use With Hart 9102S-156, 9009-Y-156 and 9009-B-156 HART
3102-1
4LHA9
Grainger
Подробнее... Stem Insert, Stem Size 1/8 In., For Use With Hart 9102S-156, 9009-Y-156 and 9009-B-156 HART
3102-2