ТЕЛ:+7 (985) 487-07-35
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Артикул
Каталог
Наименование
Описание Производитель
№ модели
4DEA6
Grainger
Подробнее... Differential Pressure Flow Sensor, Four Sensing Points, Insertion Length 9 29/32 In, Exterior Length 1/2 In, Overall Length 10 In, Mounting Flange 6 1/2 Inx 1 1/4 In, Cut a 7/8 In Diameter Hole In The Ducting to Accept The Unit, Mounting Hole Dia 3/16 In, Mounting Hole Center to Center 5 3/4 In In, Fitting Size 1/4 In Push On Nipple, For Use With VAV Controllers, 3/8 In O.D. Polyethylene Tubing, Includes 1/4 In Thick Foam Gasket KMC CONTROLS
SSS-1005
4DEA7
Grainger
Подробнее... Rotary Pneumatic Actuator, Operating PSI Range 0 to 20, Max. Air Pressure 30 psi, Nominal Spring Range 5 to 10 psi, Mounting Type Fixed, Net Force Exerted @ 0 PSI 42 lb., Net Force Exerted @ 18 PSI 85 lb., Length 8-1/4 In., Width 4-1/2 In., Height 4-1/2 In., Provides CW or CCW Motion, For Use With VAV Terminals, Small Dampers, and Valves, Includes Mounting Bracket KMC CONTROLS
MCP-36313000
4DEA8
Grainger
Подробнее... Rotary Pneumatic Actuator, Operating PSI Range 0 to 20, Max. Air Pressure 30 psi, Nominal Spring Range 8 to 13 psi, Mounting Type Fixed, Net Force Exerted @ 0 PSI 69 lb., Net Force Exerted @ 18 PSI 59 lb., Length 8-1/4 In., Width 4-1/2 In., Height 4-1/2 In., Provides CW or CCW Motion, For Use With VAV Terminals, Small Dampers, and Valves, Includes Mounting Bracket KMC CONTROLS
MCP-36315000
4DEA9
Grainger
Подробнее... Rotary Pneumatic Actuator, Operating PSI Range 0 to 20, Max. Air Pressure 30 psi, Nominal Spring Range 3 to 8 psi, Mounting Type Fixed, Net Force Exerted @ 0 PSI 25 lb., Net Force Exerted @ 18 PSI 102 lb., Length 8-1/4 In., Width 4-1/2 In., Height 4-1/2 In., Provides CW or CCW Motion, For Use With VAV Terminals, Small Dampers, and Valves, Includes Mounting Bracket KMC CONTROLS
MCP-36318000
4DED1
Grainger
Подробнее... Linear Pneumatic Actuator, Operating PSI Range 0 to 20, Max. Air Pressure 30 psi, Stroke 1-11/16 In., Nominal Spring Range 5 to 10 psi, Mounting Type Pivot, Net Force Exerted @ 0 PSI 34 lb., Net Force Exerted @ 18 PSI 67 lb., Length 5-1/2 In., Width 4-1/4 In., Height 4-1/4 In., Provides Control of VAV Terminal Units and Small Dampers, For Use With VAV Terminals, Small Dampers, and Valves, Includes Mounting Bracket KMC CONTROLS
MCP-80313101
4DED2
Grainger
Подробнее... Linear Pneumatic Actuator, Operating PSI Range 0 to 20, Max. Air Pressure 30 psi, Stroke 1-11/16 In., Nominal Spring Range 8 to 13 psi, Mounting Type Pivot, Net Force Exerted @ 0 PSI 54 lb., Net Force Exerted @ 18 PSI 47 lb., Length 5-1/2 In., Width 4-1/4 In., Height 4-1/4 In., Provides Control of VAV Terminal Units and Small Dampers, For Use With VAV Terminals, Small Dampers, and Valves, Includes Mounting Bracket KMC CONTROLS
MCP-80315101
4DED3
Grainger
Подробнее... Linear Pneumatic Actuator, Operating PSI Range 0 to 20, Max. Air Pressure 30 psi, Stroke 1-11/16 In., Nominal Spring Range 3 to 8 psi, Mounting Type Pivot, Net Force Exerted @ 0 PSI 20 lb., Net Force Exerted @ 18 PSI 81 lb., Length 5-1/2 In., Width 4-1/4 In., Height 4-1/4 In., Provides Control of VAV Terminal Units and Small Dampers, For Use With VAV Terminals, Small Dampers, and Valves, Includes Mounting Bracket KMC CONTROLS
MCP-80318101
4DED4
Grainger
Подробнее... Receiver Controller, Dual Input w/Remote Set Point Adjustment, High Main Valve Capacity, Control Type Field Selectable, Operating Temp. Range 40 to 120 F, Air Input Range 3 to 30 PSI, Height 5 1/4 In In., Width 4 3/8 In In., Depth 2 5/16 In In., Pressure 3 to 15 PSI, Air Consumption 20 SCIM, Output 3 to 15 PSIG, Includes 3/16 In (5 Mm) Nipples For 1/4 In (6 Mm) O.D. Polyethylene Tubing KMC CONTROLS
CCC-1002
6HXR4
Grainger
Подробнее... BACnet Controller, 6 Relay And 3 Universal Outputs, Voltage 24VAC, Inputs 6, Outputs 3, Display 64 x 128 Pixel Dot Matrix LCD, Dimensions 5-1/2 x 4-3/16 x 1-1/8, Includes Removable Backplate, For Use With AHU, RTU, Heat Pump, Fancoil Unit KMC CONTROLS
BAC-120063CW
6HXR5
Grainger
Подробнее... BACnet Controller, 6 Relay And 3 Universal Outputs With Humidity, Voltage 24VAC, Inputs 6, Outputs 3, Display 64 x 128 Pixel Dot Matrix LCD, Dimensions 5-1/2 x 4-3/16 x 1-1/8, Includes Removable Backplate, For Use With AHU, RTU, Heat Pump, Fancoil Unit KMC CONTROLS
BAC-120163CW