ТЕЛ:+7 (985) 487-07-35
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Артикул
Каталог
Наименование
Описание Производитель
№ модели
4DDZ5
Grainger
Подробнее... Reset Volume Controller, Sub Master, DA, Thermostat Required for Cooling DA, RA Thermostat Required for Heating, Air Consumption 11.5 SCIM At 20 PSIG, Main Air Pressure (PSIG) 15 to 30 PSIG, Push On Fittings For 1/4 In O.D. Tubing, Max. Signal Pressure (In. WC) 6, 0 to Supply Pressure Output Capability, Features Adjustable Min Max Air Flow, Accessories HFO-0006/SSS-1000 Series Flow Sensors, 4DEA3, 4DEA4, 4DEA5, 4DEA6, Includes Mounting Bracket KMC CONTROLS
CSC-2007
4DDZ6
Grainger
Подробнее... Reset Volume Controller, Sub Master, RA, Thermostat Required for Cooling RA, DA Thermostat Required for Heating, Air Consumption 11.5 SCIM At 20 PSIG, Main Air Pressure (PSIG) 15 to 30 PSIG, Push On Fittings For 1/4 In O.D. Tubing, Max. Signal Pressure (In. WC) 6, 0 to Supply Pressure Output Capability, Features Adjustable Min Max Air Flow, Accessories HFO-0006/SSS-1000 Series Flow Sensors, 4DEA3, 4DEA4, 4DEA5, 4DEA6, Includes Mounting Bracket KMC CONTROLS
CSC-2008
4DDZ7
Grainger
Подробнее... Reset Volume Controller, Sub Master, DA, Thermostat Required for Cooling DA, RA Thermostat Required for Heating, Air Consumption 14.4 SCIM At 20 PSIG, Main Air Pressure (PSIG) 15 to 30 PSIG, Push On Fittings For 1/4 In O.D. Tubing, Max. Signal Pressure (In. WC) 6, 0 to Supply Pressure Output Capability, Features Adjustable Min Max Air Flow, Accessories HFO-0006/SSS-1000 Series Flow Sensors, 4DEA3, 4DEA4, 4DEA5, 4DEA6, Includes Mounting Bracket KMC CONTROLS
CSC-2009
4DDZ8
Grainger
Подробнее... Reset Volume Controller, Sub Master, DA/RA, Thermostat Required for Cooling DA/RA, DA/RA Thermostat Required for Heating, Air Consumption 28.8 SCIM At 20 PSIG, Main Air Pressure (PSIG) 15 to 30 PSIG, Push On Fittings For 1/4 In O.D. Tubing, Max. Signal Pressure (In. WC) 6, 0 to Supply Pressure Output Capability, Features DA or RA, Adjustable Min Max, Accessories HFO-0006/SSS-1000 Series Flow Sensors, 4DEA3, 4DEA4, 4DEA5, 4DEA6, Includes Mounting Bracket KMC CONTROLS
CSC-3011-10
4DDZ9
Grainger
Подробнее... Reset Volume Controller, Sub Master, DA/RA, Thermostat Required for Cooling DA/RA, DA/RA Thermostat Required for Heating, Air Consumption 46.1 SCIM At 20 PSIG, Main Air Pressure (PSIG) 15 to 30 PSIG, Push On Fittings For 1/4 In O.D. Tubing, Max. Signal Pressure (In. WC) 6, 0 to Supply Pressure Output Capability, Features DA or RA, Adjustable Min Max, Accessories HFO-0006/SSS-1000 Series Flow Sensors, 4DEA3, 4DEA4, 4DEA5, 4DEA6, Includes Mounting Bracket KMC CONTROLS
CSC-3025-10
4DEA1
Grainger
Подробнее... Reset Volume Controller, Sub Master, DA/RA, Thermostat Required for Cooling DA/RA, DA/RA Thermostat Required for Heating, Air Consumption 28.8 SCIM At 20 PSIG, Main Air Pressure (PSIG) 15 to 30 PSIG, Push On Fittings For 1/4 In O.D. Tubing, Max. Signal Pressure (In. WC) 6, 0 to Supply Pressure Output Capability, Features DA or RA, Adjustable Min Max, Accessories HFO-0006/SSS-1000 Series Flow Sensors, 4DEA3, 4DEA4, 4DEA5, 4DEA6, Includes Mounting Bracket KMC CONTROLS
CSC-3021-10
4DEA2
Grainger
Подробнее... Reset Volume Controller, Sub Master, DA/RA, Thermostat Required for Cooling DA/RA, DA/RA Thermostat Required for Heating, Air Consumption 28.8 SCIM At 20 PSIG, Main Air Pressure (PSIG) 15 to 30 PSIG, Push On Fittings For 1/4 In O.D. Tubing, Max. Signal Pressure (In. WC) 6, 0 to Supply Pressure Output Capability, Features DA or RA, Adjustable Min Max, Accessories HFO-0006/SSS-1000 Series Flow Sensors, 4DEA3, 4DEA4, 4DEA5, 4DEA6, Includes Mounting Bracket KMC CONTROLS
CSC-3023-10
4DEA3
Grainger
Подробнее... Differential Pressure Flow Sensor, Single Sensing Point, Insertion Length 3 5/32 In, Exterior Length 1/2 In, Overall Length 4 In, Mounting Flange 3 1/2 Inx 1 1/4 In, Cut a 7/8 In Diameter Hole In The Ducting to Accept The Unit, Mounting Hole Dia 3/16 In, Mounting Hole Center to Center 2 3/4 In In, Fitting Size 1/4 In Push On Nipple, For Use With VAV Controllers, 3/8 In O.D. Polyethylene Tubing, Includes 1/4 In Thick Foam Gasket KMC CONTROLS
SSS-1002
4DEA4
Grainger
Подробнее... Differential Pressure Flow Sensor, Two Sensing Points, Insertion Length 5 13/32 In, Exterior Length 1/2 In, Overall Length 6 In, Mounting Flange 4 1/2 Inx 1 1/4 In, Cut a 7/8 In Diameter Hole In The Ducting to Accept The Unit, Mounting Hole Dia 3/16 In, Mounting Hole Center to Center 3 3/4 In In, Fitting Size 1/4 In Push On Nipple, For Use With VAV Controllers, 3/8 In O.D. Polyethylene Tubing, Includes 1/4 In Thick Foam Gasket KMC CONTROLS
SSS-1003
4DEA5
Grainger
Подробнее... Differential Pressure Flow Sensor, Three Sensing Points, Insertion Length 7 21/32 In, Exterior Length 1/2 In, Overall Length 8 In, Mounting Flange 5 1/2 Inx 1 1/4 In, Cut a 7/8 In Diameter Hole In The Ducting to Accept The Unit, Mounting Hole Dia 3/16 In, Mounting Hole Center to Center 4 3/4 In In, Fitting Size 1/4 In Push On Nipple, For Use With VAV Controllers, 3/8 In O.D. Polyethylene Tubing, Includes 1/4 In Thick Foam Gasket KMC CONTROLS
SSS-1004