46E328
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 12-1/4, CFM @ 1.000-In. SP 2527, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 3.53, Motor HP 3, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 28-5/16, Housing Width (In.) 22-13/16, Housing Length (In.) 24-3/4, Discharge Height (In.) 8-9/16, Discharge Width (In.) 13-3/4, Inlet Dia. (In.) 12-7/8, Wheel Width (In.) 4-3/4 CHICAGO BLOWER
122-3HP
46E329
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 15, CFM @ 1.000-In. SP 3784, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 5.72, Motor HP 5, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 29-5/16, Housing Width (In.) 27-7/16, Housing Length (In.) 29-11/16, Discharge Height (In.) 9-3/8, Discharge Width (In.) 16-11/16, Inlet Dia. (In.) 15-3/4, Wheel Width (In.) 5-1/4 CHICAGO BLOWER
150-5HP
46E330
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 16-1/2, CFM @ 1.000-In. SP 4645, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 8.67, Motor HP 7-1/2, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 32, Housing Width (In.) 29-7/8, Housing Length (In.) 32-1/2, Discharge Height (In.) 10, Discharge Width (In.) 18-7/16, Inlet Dia. (In.) 17-5/8, Wheel Width (In.) 5-7/8 CHICAGO BLOWER
165-7.5HP
46E331
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 16-1/2, CFM @ 1.000-In. SP 6330, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 11.5, Motor HP 10, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 33, Housing Width (In.) 29-7/8, Housing Length (In.) 32-1/2, Discharge Height (In.) 11-1/4, Discharge Width (In.) 18-7/16, Inlet Dia. (In.) 17-5/8, Wheel Width (In.) 5-7/8 CHICAGO BLOWER
165-10HP
46E332
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 18-1/4, CFM @ 1.000-In. SP 7610, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 16.6, Motor HP 15, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 37-5/16, Housing Width (In.) 32-3/4, Housing Length (In.) 35-15/16, Discharge Height (In.) 11-3/4, Discharge Width (In.) 20-3/8, Inlet Dia. (In.) 19-5/8, Wheel Width (In.) 7-1/8 CHICAGO BLOWER
182-15HP
46E333
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 18-1/4, CFM @ 1.000-In. SP 9960, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 21.9, Motor HP 20, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 38-5/16, Housing Width (In.) 32-3/4, Housing Length (In.) 35-15/16, Discharge Height (In.) 13-7/32, Discharge Width (In.) 20-3/8, Inlet Dia. (In.) 19-5/8, Wheel Width (In.) 7-1/8 CHICAGO BLOWER
182-20HP
46E334
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 18-1/4, CFM @ 1.000-In. SP 11, 710, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 27.8, Motor HP 25, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 43-1/8, Housing Width (In.) 32-3/4, Housing Length (In.) 35-15/16, Discharge Height (In.) 14-1/4, Discharge Width (In.) 20-3/8, Inlet Dia. (In.) 19-5/8, Wheel Width (In.) 7-1/8 CHICAGO BLOWER
182-25HP
46E335
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 20, CFM @ 1.000-In. SP 13, 169, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 33.2, Motor HP 30, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 43-5/16, Housing Width (In.) 35-11/16, Housing Length (In.) 39-1/4, Discharge Height (In.) 14-11/32, Discharge Width (In.) 22-3/8, Inlet Dia. (In.) 21-5/8, Wheel Width (In.) 7-3/4 CHICAGO BLOWER
200-30HP
46E336
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 20, CFM @ 1.000-In. SP 15, 480, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 44.2, Motor HP 40, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 46-3/8, Housing Width (In.) 35-11/16, Housing Length (In.) 39-1/4, Discharge Height (In.) 15-5/8, Discharge Width (In.) 22-3/8, Inlet Dia. (In.) 21-5/8, Wheel Width (In.) 7-3/4 CHICAGO BLOWER
200-40HP
46E337
Grainger
Подробнее... High Pressure Blower, Backward Incline, Wheel Dia. (In.) 22-1/4, CFM @ 1.000-In. SP 18, 230, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 54.7, Motor HP 50, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 46-11/16, Housing Width (In.) 39-3/8, Housing Length (In.) 43-1/2, Discharge Height (In.) 15-13/16, Discharge Width (In.) 24-7/8, Inlet Dia. (In.) 24-1/4, Wheel Width (In.) 8-13/16 CHICAGO BLOWER
222-50HP