Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
18K873 Grainger |
|
Surge Suppressor, ModularNominal Discharge Current 20kA, Voltage 277/480, Phase 3YMax. Continuing Operating Voltage 320 L-N, 550 L-L, Voltage Protection Rating 1200V (L-N), 1800 (L-L), 1000V (N-G), 1200V (L-G)Modes of Protection All modes protected, Mounting Style Panelboard, 3/4 In. Straight Nipple, Material of Construction Aluminum, IP65 (NEMA 4)Length 10.40, Width 10.32, Depth 3.25, Standards CE, IEC 61643-1, UL 1449 Edition 3 Listed Type 1/2 |
ERICO TDX300S277/480 |
18K874 Grainger |
|
Surge Suppressor, ModularNominal Discharge Current 20kA, Voltage 120/208, Phase 3YMax. Continuing Operating Voltage 170 L-N, 276 L-L, Voltage Protection Rating 800V (L-N), 1200 (L-L), 700V (N-G), 800V (L-G)Modes of Protection All modes protected, Mounting Style Panelboard, 3/4 In. Straight Nipple, Material of Construction Aluminum, IP65 (NEMA 4)Length 10.40, Width 10.32, Depth 3.25, Standards CE, IEC 61643-1, UL 1449 Edition 3 Listed Type 1/2 |
ERICO TDX400S120/208 |
18K875 Grainger |
|
Surge Suppressor, ModularNominal Discharge Current 20kA, Voltage 120/240, Phase 1SMax. Continuing Operating Voltage 170 L-N, 276 L-L, Voltage Protection Rating 800V (L-N), 1200 (L-L), 700V (N-G), 800V (L-G)Modes of Protection All modes protected, Mounting Style Panelboard, 3/4 In. Straight Nipple, Material of Construction Aluminum, IP65 (NEMA 4)Length 10.40, Width 10.32, Depth 3.25, Standards CE, IEC 61643-1, UL 1449 Edition 3 Listed Type 1/2 |
ERICO TDX400S120/240 |
18K876 Grainger |
|
Surge Suppressor, ModularNominal Discharge Current 20kA, Voltage 277/480, Phase 3YMax. Continuing Operating Voltage 320 L-N, 550 L-L, Voltage Protection Rating 1200V (L-N), 1800 (L-L), 1000V (N-G), 1200V (L-G)Modes of Protection All modes protected, Mounting Style Panelboard, 3/4 In. Straight Nipple, Material of Construction Aluminum, IP65 (NEMA 4)Length 10.40, Width 10.32, Depth 3.25, Standards CE, IEC 61643-1, UL 1449 Edition 3 Listed Type 1/2 |
ERICO TDX400S277/480 |
18K877 Grainger |
|
Surge Suppressor, CompactNominal Discharge Current 20kA, Voltage 120/240, Phase 1SMax. Continuing Operating Voltage 150 L-N, 300 L-L, Voltage Protection Rating 800V (L-N), 1500 (L-L)Modes of Protection L-N, L-L, Mounting Style Panelboard, 3/4" Straight Nipple with Conduit Nut for Mounting Through Standard 1.14 In. dia. Knockout, Material of Construction UV Stabilized ThermoplasticLength 2.44, Width 3.90, Depth 3.43, Standards CE, UL 1449 Edition 3 Listed Type 1/2, cUL |
ERICO SES40120/240SP |
18K878 Grainger |
|
Surge Suppressor, CompactNominal Discharge Current 20kA, Voltage 120/208, Phase 3YMax. Continuing Operating Voltage 150 L-N, 300 L-L, Voltage Protection Rating 800V (L-N), 1800 (L-L), 800V (N-G), 1500V (L-G)Modes of Protection All modes protected, Mounting Style Panelboard, 3/4" Straight Nipple with Conduit Nut for Mounting Through Standard 1.14 In. dia. Knockout, Material of Construction UV Stabilized ThermoplasticLength 2.44, Width 3.90, Depth 3.43 |
ERICO SES402083P |
18K879 Grainger |
|
Surge Suppressor, CompactNominal Discharge Current 20kA, Voltage 277/480, Phase 3YMax. Continuing Operating Voltage 340 L-N, 590 L-L, Voltage Protection Rating 1200V (L-N), 2000 (L-L), 1500V (N-G), 2000V (L-G)Modes of Protection All modes protected, Mounting Style Panelboard, 3/4" Straight Nipple with Conduit Nut for Mounting Through Standard 1.14 In. dia. Knockout, Material of Construction UV Stabilized ThermoplasticLength 2.44, Width 3.90, Depth 3.43 |
ERICO SES404803P |