ТЕЛ:+7 (985) 487-07-35
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

AC Drive, 2 HP

AC Drive, Motor Power Rating 2 HP, Output Current 3.7 Amps, Height 10.3 Inches, Width 5.9 Inches, Depth 5.7 Inches, 380 to 480 VAC, 50/60 hz, NEMA 4, Three Phase Input
Артикул:
5HV45
Каталог:
Grainger
Производитель:
FUJI
Номер модели:
FRN002G11W-4UX
Страна производства:
Not Available
Вес (кг):
3.32
5HV45 AC Drive, 2 HP
Спецификация:
Item: AC Drive
Drive Type: Adjustable Frequency Variable Torque
Max. HP: 2
Max. Output Amps: 3.7
Voltage: 380-480
Voltage Output: 380-480
Input Phase AC: 3
Output Phase AC: 3
Enclosure: NEMA 4
Height (In.): 10.3
Width (In.): 5.9
Depth (In.): 5.70
Functions: Operating Method/Frequency Setting, Base and Top Frequency, Maximum Output Frequency, Torque Boost, Fault Memory, DC Braking, Acceleration/Deceleration, Motor Sound Adjustment, Maximum Output Voltage, Slip Compensation, Torque Limit Control, Sensorless Torque Vector, Jump Frequency, Automatic Deceleration Time, Automatic Pattern Operation
Protection: Overcurrent, Overvoltage, Undervoltage, Inverter Heatsink and Brake Resistor Overheating
Displays: Input Volts, Output Amps, RPM, Frequency or Conveyor Speed

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
4XJL2
Grainger
Подробнее... Output Filter, dV/dT, Voltage 600V & Below, Amps 4, HP 2, Phase Three, Enclosure Type UL Type 1, Watts Loss 75, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is 100 Ft. to 1000 Ft., Height 9 In., Width 5.5 In., Depth 10 In., Standards UL Listed, CE certified V1K FILTERS
V1K4A01
4XRT8
Grainger
Подробнее... Input Line Reactor, Low Z, Voltage 460/480, Amps 3.4, HP 2, Phase Three, Enclosure Type Open, Watts Loss 19, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 4 In., Width 4.18 In., Depth 3.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA1L
4XRX6
Grainger
Подробнее... Input Line Reactor, High Z, Voltage 460/480, Amps 3.4, HP 2, Phase Three, Enclosure Type Open, Watts Loss 33, Impedance 5%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 4 In., Width 4.18 In., Depth 3.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA1H
4XTL7
Grainger
Подробнее... Output Load Reactor, Voltage 480, Amps 3.4, HP 2, Phase Three, Enclosure Type Open, Impedance 1.5%, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is Under 100 Ft., Height 4 In., Width 4.18 In., Depth 3.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA1P
4XTV1
Grainger
Подробнее... Output Filter, dV/dT, Voltage 600V & Below, Amps 4, HP 2, Phase Three, Enclosure Type Open, Watts Loss 75, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is 100 Ft. to 1000 Ft., Height 9 In., Width 5.5 In., Depth 7.25 In., Standards UL Listed, CE certified V1K FILTERS
V1K4A00
Обратите внимание:
13E652
AC Drive, 3 HP, NEMA 4X, 9.0A, 230V 3 Ph
4UAG9
ACDrive, Var.Freq, 5HP, 16.7A, 200-240V, 3PH
5HV45
AC Drive, 2 HP
5WJJ8
AC Drive, Var Freq, 0.5HP, 2.4A, 120V, 1Ph