2GNU1 QO142M200
SQUARE D
Load Center, 200 A
Load Center, Current Rating 200 Amps, Copper Wire Size #4-250 AWG, Aluminum Wire Size #4-250 AWG, Flush Cover 1D435, Maximum Number of Single Pole Breakers 24, Number of Spaces 24, Surface Cover 1D436, Ground Bar Kit 1D369, Height 30.00 Inches, Width 14.25 Inches, Depth 3.75 Inches, NEMA 1 Indoor Model, Single Phase, Main Breaker
Артикул:
5F684
Каталог:
Grainger
Производитель:
SQUARE D
Номер модели:
QO124M200
Страна производства:
USA
Вес (кг):
8.39

Спецификация:
Item: Load Center |
Type: Main Circuit Breaker |
Amps: 200 |
RMS Symmetrical Amp Rating: 22000 |
Phase: 1 |
Bus: One Piece |
Main Circuit Breaker: Factory Installed |
Mains: Convertible |
Circuit Breaker Type: QO |
Enclosure: Indoor |
Number of Spaces: 24 |
Max. No. of 1 Pole Breakers: 24 |
Max. No. of Tandem Breakers: 0 |
Copper (AWG/kcmil): 4 to 250 |
Aluminum Wire (AWG/kcmil): 4 to 250 |
Bus Material: Copper Plated |
Material of Construction: Shielded Copper |
NEMA Rating: 1 |
Cover Type: Low Profile with Automatic Flush Adjustment |
Flush Cover: 1D435 |
Surface Cover: 1D436 |
Height (In.): 29.86 |
Width (In.): 14.25 |
Depth (In.): 3.75 |
Ground Bar Kit: 1D369 |
Rotated For: Top or Bottom Feed |
Federal Specification: W-P-115c as Type 1 Class 2 |
Дополнительные аксессуары: | ||||
Артикул Каталог |
Наименование |
Описание | Производитель № модели |
|
---|---|---|---|---|
1D301 Grainger |
QO Circuit Breaker, Current Rating 20 Amps, Number of Poles 2, Minimum Wire Size 14 AWG, Maximum Wire Size 8 AWG, 10000 Amps Interrupting Rating | SQUARE D QO220 |
||
1D369 Grainger |
QO Ground Bar Kit, Type PK15GTA, Current Rating 225 Amperes, Number of Terminals 15, For NQOD Panel Board, 125 Amperes QO Load Centers | SQUARE D PK15GTA |
||
1D435 Grainger |
QO Indoor Cover, Mounting Style Flush, For Indoor Load Centers 1D772, 5F683, 5F694, 5F684, 5F697, 5F688, 5F700, 5F664, 5F679, 5F690, 5F651, 5F692 and 5F685 | SQUARE D QOC30UF |
||
1D436 Grainger |
QO Indoor Cover, Mounting Style Surface, For 30 Space Indoor Load Centers 5F680, 5F681, 5F658, 5F656, 5F672, 5F662 and 5F677, 150/200 Amps | SQUARE D QOC30US |
||
1D443 Grainger |
QO And NQOD Filler Plate, Fills Opening in Covers | SQUARE D QOFP |
Альтернативная продукция:
Load Center, Main Circuit Breaker, Amps 200, Voltage 120/240, Phase 1, Main Circuit Breaker Factory Installed, Mains Convertible, Circuit Breaker Type QOM, Number of Spaces 42, Copper (AWG/kcmil) 4 to 300, Aluminum Wire (AWG/kcmil) 4 to 300, Bus Material Tin-Plated Copper, Material of Construction Shielded Copper, NEMA Rating 1, Flush Cover 1D441, Surface Cover 1D442, Height (In.) 37.98, Width (In.) 14.25, Depth (In.) 3.75, Ground Bar Kit 1D371
Load Center, Current Rating 200 Amps, Copper Wire Size #4-250 AWG, Aluminum Wire Size #4-250 AWG, Flush Cover 1D435, Maximum Number of Single Pole Breakers 40, Maximum Number of Tandem Breakers 10, Number of Spaces 30, Surface Cover 1D436, Ground Bar Kit 1D371, Height 30.00 Inches, Width 14.25 Inches, Depth 3.75 Inches, NEMA 1 Indoor Model, Single Phase, Main Breaker
Load Center, Current Rating 200 Amps, Copper Wire Size #4-250 AWG, Aluminum Wire Size #4-250 AWG, Flush Cover 1D435, Maximum Number of Single Pole Breakers 30, Number of Spaces 30, Surface Cover 1D436, Ground Bar Kit 1D370, Height 30.00 Inches, Width 14.25 Inches, Depth 3.75 Inches, NEMA 1 Indoor Model, Single Phase, Main Breaker
Load Center, Current Rating 200 Amps, Copper Wire Size #4-250 AWG, Aluminum Wire Size #4-250 AWG, Flush Cover 1D435, Maximum Number of Single Pole Breakers 40, Number of Spaces 40, Surface Cover 1D440, Ground Bar Kit 1D371, Height 34.00 Inches, Width 14.25 Inches, Depth 3.75 Inches, NEMA 1 Indoor Model, Single Phase, Main Breaker