Automatic Standby Generator, 14LP/13NG kW

Automatic Standby Generator, Engine Cooling Air, 14 LP/13 NG kW, 14 LP/13 NG kVA Rating, Voltage 120/240, Height 29 In., Width 25 In., Length 48 In., Enclosure Material Steel, Fuel Type Natural Gas/ LP, Generac OHVI Engine Brand, Engine Size 992cc, Engine RPM 3600, Amps @ 120/240V, 1 Phase LP 116.6/58.3 (NG 108.3/54.2), NG Consumption @ Half Load 220 cu. ft./hr., LP Consumption @ Half Load 2.3 gph, 60 Hz, Sound Level dBA 66Automatic Volts Regulation Yes, Battery Included No
Артикул:
2ZMG6
Каталог:
Grainger
Производитель:
GENERAC
Номер модели:
5884
Страна производства:
USA
Вес (кг):
233.64
2ZMG6 Automatic Standby Generator, 14LP/13NG kW
Спецификация:
Item: Automatic Standby Generator
Engine Cooling Method: Air
kW: 14 LP/13 NG
kVA Rating: 14 LP/13 NG
Voltage: 120/240
Height: 29"
Width: 25"
Length: 48"
Enclosure Material: Steel
Fuel Type: Natural Gas/ LP
Engine Brand: Generac OHVI
Engine Size: 992cc
Engine RPM: 3600
Amps @ 120/240V, 1 Phase: LP 116.6/58.3 (NG 108.3/54.2)
NG Consumption @ Half Load: 220 cu. ft./hr.
LP Consumption @ Half Load: 2.3 gph
Hz: 60
Sound Level dBA: 66
Automatic Volts Regulation: Yes
Battery Included: No
12VDC Battery Charger: Yes
Battery Requirements: 525 CCA
Engine (Block Heater): Yes or No
Fault Indicator Lights: Yes
Fuel NPT Pipe Connection Sz.: 1/2"
High Temp. Alarm: Yes
Low Oil Pressure Alarm: Yes
Min. Gas Pressure @ Generator (In WC): 10 to 12/5 to 7
Over Crank Protection: Yes
Phase: 1
Power Factor: 1
Repeat of Exercise Cycle: 7 Days
Run Time Hour Meter: Yes
Main Circuit Breaker: Fuse Built Into Controller; Circuit Breakers are Located in the Transfer Switch
Over Speed: Yes
Includes: 1 Ft Flexible Fuel Line Connector
Standards: UL, CSA, NEMA, EGSA

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
2ZMH1
Grainger
Подробнее... Automatic Transfer Switch, Voltage 240, Phase 1, NEMA Enclosure Type 3R, Max. Wattage 24000, Load Transition Type Open, Standard Installation, Max. Amps 100, Height 20 In., Width 14-5/8 In., Depth 7 In., Enclosure Material Aluminum, 2-Wire Start No, Warranty 2 yr., Automatic Exerciser Yes, Gray, For Use With 8 to 22kWLockable No, Manual Override YesMax. Wire Size 2/0-14 AWG, Repeat of Exercise Cycle 7, Sensing Generator Hz No, Sensing Line Failure 0.6, Sensing Under Volts 0.6 GENERAC
RTSR100A3
2ZMH2
Grainger
Подробнее... Automatic Transfer Switch, Voltage 240, Phase 1, NEMA Enclosure Type 3R, Max. Wattage 48000, Load Transition Type Open, Standard Installation, Max. Amps 200, Height 20 In., Width 14-5/8 In., Depth 7 In., Enclosure Material Aluminum, 2-Wire Start No, Warranty 2 yr., Automatic Exerciser Yes, Gray, For Use With 8 to 48kWLockable No, Manual Override YesMax. Wire Size 400 MCM, Repeat of Exercise Cycle 7, Sensing Generator Hz No, Sensing Line Failure 0.6, Sensing Under Volts 0.6, Time Delay Neutral No GENERAC
RTSR200A3
2ZMH3
Grainger
Подробнее... Automatic Transfer Switch, Voltage 240, Phase 1, NEMA Enclosure Type 3R, Max. Wattage 24000, Load Transition Type Open, Standard Installation, Max. Amps 100, Height 20 In., Width 14-5/8 In., Depth 7 In., Enclosure Material Aluminum, 2-Wire Start No, Warranty 1 yr., Automatic Exerciser Yes, Gray, For Use With 8 to 22kWLockable No, Manual Override YesMax. Wire Size 2/0-14 AWG, Repeat of Exercise Cycle 7, Sensing Generator Hz No, Sensing Line Failure 0.6, Sensing Under Volts 0.6 GENERAC
RTSY100A3
2ZMJ1
Grainger
Подробнее... Automatic Transfer Switch with Load Center, Voltage 240, Phase 1, NEMA Enclosure Type 1, Max. Wattage 24000, Load Transition Type Open, Standard Installation, Max. Amps 100, Height 29-1/4 In., Width 12-1/2 In., Depth 7 In., Enclosure Material Steel, 2-Wire Start No, Warranty 1 yr., Automatic Exerciser Yes, Gray, For Use With 8 to 17kW, Includes 14 Circuit Load Center, Lockable No, Manual Override YesMax. Wire Size 2/0-14 AWG, Repeat of Exercise Cycle 7, Sensing Generator Hz No GENERAC
RTG14EZA1
2ZNX7
Grainger
Подробнее... Generator Battery Warmer, For Use With Generac Air-Cooled Series, Includes 28 In. Battery Warmer with Terminals and Filter GENERAC
5635
Альтернативная продукция:
11C852  40326
BRIGGS & STRATTON
Automatic Standby Generator, Engine Cooling Air, 12 kW, 12 kVA Rating, Voltage 240, Height 39 In., Width 40 In., Length 35 In., Enclosure Material Steel, Fuel Type Natural Gas/ LP, Briggs and Stratton Engine Brand, Engine Size 803cc, Engine RPM 3600, Amps @ 120/240V, 1 Phase 50.0/45.8, NG Consumption @ Half Load 93 cu. ft./hr., LP Consumption @ Half Load 1.35 gph, 60 Hz, Sound Level dBA 72, 4 yr. Warranty, Automatic Volts Regulation Yes, Battery Included No, 12VDC Battery Charger Yes

18K882  40337
BRIGGS & STRATTON
Automatic Standby Generator, Engine Cooling Air, 16 kW, 16 kVA Rating, Voltage 240, Height 32 In., Width 36 In., Length 52 In., Enclosure Material Steel, Fuel Type Natural Gas/ LP, Briggs and Stratton Engine Brand, Engine Size 993cc, Engine RPM 3600, Amps @ 120/240V, 1 Phase 133.3/66.6, NG Consumption @ Half Load 145 cu. ft./hr., LP Consumption @ Half Load 1.9 gph, 60 Hz, Sound Level dBA 65Automatic Volts Regulation Yes, Battery Included No, 12VDC Battery Charger Yes

2ZMG7  6248
GENERAC
Automatic Standby Generator, Engine Cooling Air, 17 LP/16 NG kW, 17 LP/16 NG kVA Rating, Voltage 240V, Height 29 In., Width 25 In., Length 48 In., Enclosure Material Steel, Fuel Type Natural Gas/ LP, Generac OHVI Engine Brand, Engine Size 992cc, Engine RPM 3600, Amps @ 120/240V, 1 Phase LP 70.8 /66.6 NG, NG Consumption @ Half Load 261 cu. ft./hr., LP Consumption @ Half Load 2.57 gph, 60 Hz, Sound Level dBA 66Automatic Volts Regulation Yes, Battery Included No, 12VDC Battery Charger Yes